KRATOS REV6 BIG SCREEN — SINGLE-FILE FACTORY TEST
Version: 0.6.7-kratos-v6b-test / factory packaging revision 1

PURPOSE
One combined BIN for manufacturer testing on ONE matching Rev6 big-screen unit.
It contains the bootloader, partition table, application, dashboard and blank
factory state. It is not a universal image and not approved for batch production.
Do not put this image into the existing Kratos Rev6/Rev7 website installer or a
miner's application-only OTA upload field.

EXACT HARDWARE
VastBTC yyslupingB++, ESP32-S3, actual 32 MiB flash, 480x320 display,
4x BM1370, positive legacy Rev6 regulator identification.
NOT ordinary 16 MiB Rev6, Rev7, the 320x170 model, Hammer or Nexus.
Never force a flash past a controller, flash-size or security mismatch.

ONE FILE / ONE ADDRESS
File: kratos-rev6-big-screen-0.6.7-factory-test.bin
Length: 33,554,432 bytes (32 MiB)
Write address: 0x0
SPI mode: DIO     SPI frequency: 40 MHz     Flash size: 32 MB

WARNING: FULL FACTORY RESET
This writes the whole 32 MiB address space, including bootloader and partitions.
It clears Wi-Fi, pool/payout, tuning, authenticator and custom dashboard/artwork
settings, old OTA slots and crash data. It does not preserve a previous install.
On a configured unit, offer a private recovery copy before proceeding. A backup
contains secrets and must not be sent to us or included in production images.
Do not clone a configured miner's full flash to other units.

MANUFACTURER FLASHING TOOLS
A programmer that supports ESP32-S3 and 32 MiB can use the BIN at 0x0. This is
the combined-file route; choose no additional app/web/partition files.
Use Espressif esptool v4.13.0 for the command sequence below. These are commands
for the human operator, not commands that were executed on a miner by Kratos.
Replace PORT with the actual COM port or /dev/cu.* device, and run from the folder
containing the BIN. Use a reliable USB data cable and the board's required power.
Enter the manufacturer's documented USB download mode; do not guess button pins.

1. Install the pinned utility in a virtual environment:
   python -m pip install esptool==4.13.0

2. Inspect the actual unit before any write:
   python -m esptool --chip esp32s3 --port PORT --after no_reset chip_id
   python -m esptool --chip esp32s3 --port PORT --after no_reset flash_id
   python -m esptool --chip esp32s3 --port PORT --after no_reset get_security_info

   Require ESP32-S3, detected 32 MB flash, Secure Boot disabled and flash
   encryption disabled. If identity/security cannot be established, stop and use
   the manufacturer's supported provisioning process. Do not use --force or burn
   eFuses. Physically confirm PCB/regulator/display and power supply separately.

3. Verify SHA256SUMS against this exact downloaded BIN. Then, only after the
   operator accepts the factory reset, write the single combined image:
   python -m esptool --chip esp32s3 --port PORT --baud 460800 --after no_reset write_flash --flash_mode dio --flash_freq 40m --flash_size 32MB 0x0 kratos-rev6-big-screen-0.6.7-factory-test.bin

4. Verify the complete programmed image before restarting:
   python -m esptool --chip esp32s3 --port PORT --baud 460800 --after no_reset verify_flash 0x0 kratos-rev6-big-screen-0.6.7-factory-test.bin

   Do not restart on a write/readback failure. Keep the exact vendor big-screen
   recovery image and its documented recovery procedure available.
   If verification passes, close the serial tool, leave download mode and restart
   the unit using its normal manufacturer procedure.

FIRST BOOT / 6 TH/s TARGET
This release CORRECTS the earlier factory clock from 600 MHz (~4.8 TH/s) to
750 MHz (the intended ~6 TH/s class). Steady core voltage stays 1150 mV and
the startup minimum stays 1200 mV. These voltage settings are NOT yet validated
at 750 MHz on this exact board. Verify accepted shares, errors, temperatures,
input power and stability on one unit before batch use; do not assume 6 TH/s
is guaranteed from the clock setting alone. Do not raise voltage or power limits
without the manufacturer's electrical validation.

The 800 MHz absolute ceiling and nominal 100 W Rev6 profile are unchanged.
Selectable clocks include the existing lower clocks and 625/650/675/700/725/750.
There is no 1000 MHz / 8 TH/s profile. In a settings-preserving application update,
existing NVS frequency and voltage values would stay unchanged. This combined
factory BIN intentionally resets NVS and therefore starts at 750/1150.

The fresh setup access point is named Nerdaxe_XXXX, with a per-unit suffix.
The code starts a local setup web server; use the IP shown by the unit/AP network.
The stock example Wi-Fi fallback is not a customer credential. Configure actual
Wi-Fi and payout details locally. Payout is blank; mining is not started until
network and a payout/pool configuration have been supplied. Each unit must be
configured separately; no owner wallet, Wi-Fi credentials or private key is baked in.

BEFORE REPEATING ON A BATCH
Have the manufacturer report: PCB/regulator/flash identification; successful
write/readback and cold boot; full 480x320 orientation/colours/backlight; local
dashboard version 0.6.7-kratos-v6b-test; real temperatures/fans; advancing accepted
shares; measured power and stability at the intended 6 TH/s tune; reboot/settings
persistence; and recovery to the exact matching vendor image. A build or readback
pass alone is not physical mining, thermal or recovery validation.

This 0.6.7 file includes the reviewed native LCD and dashboard presentation update.
Do not mix an app from one version with another version's dashboard.

Source, hashes and current status:
https://kratos.mineshop.eu/firmware/rev6-big-screen.html

DESIGN UPDATE 0.6.7
Dark graphite and red spacecraft-control-board LCD and matching web theme,
with the original Kratos artwork and real telemetry. Missing/zero/stale readings
stay distinct in the dashboard; no decorative gauge invents a live value.
Previous 0.6.5/0.6.6 images stay unchanged. Do not mix app/www versions.