KRATOS REV6 BIG SCREEN — SINGLE-FILE FACTORY TEST Version: 0.6.6-kratos-v6b-test / factory packaging revision 1 PURPOSE One combined BIN for manufacturer testing on ONE matching Rev6 big-screen unit. It contains the bootloader, partition table, application, dashboard and blank factory state. It is not a universal image and not approved for batch production. Do not put this image into the existing Kratos Rev6/Rev7 website installer or a miner's application-only OTA upload field. EXACT HARDWARE VastBTC yyslupingB++, ESP32-S3, actual 32 MiB flash, 480x320 display, 4x BM1370, positive legacy Rev6 regulator identification. NOT ordinary 16 MiB Rev6, Rev7, the 320x170 model, Hammer or Nexus. Never force a flash past a controller, flash-size or security mismatch. ONE FILE / ONE ADDRESS File: kratos-rev6-big-screen-0.6.6-factory-test.bin Length: 33,554,432 bytes (32 MiB) Write address: 0x0 SPI mode: DIO SPI frequency: 40 MHz Flash size: 32 MB WARNING: FULL FACTORY RESET This writes the whole 32 MiB address space, including bootloader and partitions. It clears Wi-Fi, pool/payout, tuning, authenticator and custom dashboard/artwork settings, old OTA slots and crash data. It does not preserve a previous install. On a configured unit, offer a private recovery copy before proceeding. A backup contains secrets and must not be sent to us or included in production images. Do not clone a configured miner's full flash to other units. MANUFACTURER FLASHING TOOLS A programmer that supports ESP32-S3 and 32 MiB can use the BIN at 0x0. This is the combined-file route; choose no additional app/web/partition files. Use Espressif esptool v4.13.0 for the command sequence below. These are commands for the human operator, not commands that were executed on a miner by Kratos. Replace PORT with the actual COM port or /dev/cu.* device, and run from the folder containing the BIN. Use a reliable USB data cable and the board's required power. Enter the manufacturer's documented USB download mode; do not guess button pins. 1. Install the pinned utility in a virtual environment: python -m pip install esptool==4.13.0 2. Inspect the actual unit before any write: python -m esptool --chip esp32s3 --port PORT --after no_reset chip_id python -m esptool --chip esp32s3 --port PORT --after no_reset flash_id python -m esptool --chip esp32s3 --port PORT --after no_reset get_security_info Require ESP32-S3, detected 32 MB flash, Secure Boot disabled and flash encryption disabled. If identity/security cannot be established, stop and use the manufacturer's supported provisioning process. Do not use --force or burn eFuses. Physically confirm PCB/regulator/display and power supply separately. 3. Verify SHA256SUMS against this exact downloaded BIN. Then, only after the operator accepts the factory reset, write the single combined image: python -m esptool --chip esp32s3 --port PORT --baud 460800 --after no_reset write_flash --flash_mode dio --flash_freq 40m --flash_size 32MB 0x0 kratos-rev6-big-screen-0.6.6-factory-test.bin 4. Verify the complete programmed image before restarting: python -m esptool --chip esp32s3 --port PORT --baud 460800 --after no_reset verify_flash 0x0 kratos-rev6-big-screen-0.6.6-factory-test.bin Do not restart on a write/readback failure. Keep the exact vendor big-screen recovery image and its documented recovery procedure available. If verification passes, close the serial tool, leave download mode and restart the unit using its normal manufacturer procedure. FIRST BOOT / 6 TH/s TARGET This combined file reuses the existing application unchanged. Its blank-state clock default is 600 MHz and its steady-state core-voltage default is 1150 mV (the existing startup sequence initially requests at least 1200 mV). It is NOT a pre-tuned 6 TH/s production preset. The 800 MHz ceiling includes the usual approximately 750 MHz / 6 TH/s range, but the manufacturer must validate voltage, power, cooling and stable shares on the actual board before selecting that tune. No 1000 MHz / 8 TH/s profile is added. The fresh setup access point is named Nerdaxe_XXXX, with a per-unit suffix. The code starts a local setup web server; use the IP shown by the unit/AP network. The stock example Wi-Fi fallback is not a customer credential. Configure actual Wi-Fi and payout details locally. Payout is blank; mining is not started until network and a payout/pool configuration have been supplied. Each unit must be configured separately; no owner wallet, Wi-Fi credentials or private key is baked in. BEFORE REPEATING ON A BATCH Have the manufacturer report: PCB/regulator/flash identification; successful write/readback and cold boot; full 480x320 orientation/colours/backlight; local dashboard version 0.6.6-kratos-v6b-test; real temperatures/fans; advancing accepted shares; measured power and stability at the intended 6 TH/s tune; reboot/settings persistence; and recovery to the exact matching vendor image. A build or readback pass alone is not physical mining, thermal or recovery validation. This 0.6.6 file includes the reviewed native LCD and dashboard presentation update. Do not mix an app from one version with another version's dashboard. Source, hashes and current status: https://kratos.mineshop.eu/firmware/rev6-big-screen.html DESIGN UPDATE 0.6.6 This package includes the Opus-designed native 480x320 dashboard and the matching web presentation (larger readouts, explicit stale/missing reading states). It does not add the concept preview's thermal bands, 6 TH/s target line or redesigned Screen editor navigation. Existing editing and settings controls remain. The 0.6.5 files remain separate and unchanged. Do not mix app/www versions.